Fire Supression System
Fire Supression System

Fire Supression System

Price 15000 INR/ Unit

MOQ : as per customer requirement Unit

Fire Supression System Specification

  • Coverage Area
  • Up to 1000 sq.ft. per unit (depending on configuration)
  • Fire Class
  • A, B, C, E (Electrical)
  • Technology
  • Automatic Gas Suppression
  • Connectivity Type
  • Wired connectivity with Panel
  • Working Temperature
  • -30C to +55C
  • Energy Efficiency Rating
  • High
  • Shape
  • Cylinder
  • Voltage
  • 24V DC
  • Control Type
  • Automatic & Manual
  • Features
  • Non-toxic, Rapid Activation, Clean Agent, Minimal Residue
  • Installation Type
  • Fixed Ceiling/Wall Mounted
  • Fire Extinguisher Type
  • Clean Agent/Novec 1230/FM200/Gaseous
  • Coating Type
  • Epoxy Powder Coated
  • Operating Pressure
  • Up to 200 Bar
  • Mounting Type
  • Wall/Ceiling Mounted
  • Application
  • Industrial, Commercial Buildings, Server Rooms, Electrical Panels
  • Max Flow Rate
  • Up to 20 L/min
  • Diameter
  • Customizable (typically 25mm - 80mm for piping)
  • Capacity
  • 2kg to 120kg
  • Pressure
  • 15-200 Bar (depending on system type)
 

Fire Supression System Trade Information

  • Payment Terms
  • Telegraphic Transfer (T/T)
  • Supply Ability
  • 20 Units Per Week
  • Delivery Time
  • 5 Days
  • Main Export Market(s)
  • Australia, North America, Eastern Europe, South America, Africa, Central America, Middle East, Western Europe, Asia
  • Main Domestic Market
  • All India
 

About Fire Supression System

We always strive to achieve higher benchmarks in the industry by installing and supplying an utmost range of Fire Suppression System. These systems are largely used to protect areas containing valuable equipments such as data processing rooms, telecommunication switches, and process control rooms. Our Fire Suppression System is designed and manufactured by our professionals as per the set industry norms using supreme grade materials. Our clients can avail these systems from us at a pocket friendly price.

Features:

  • Quick extinguishing
  • Enabled alarm system
  • Automatic fire detector


Cutting-Edge Detection and Fast Response

The system employs sensitive smoke and heat detectors to identify fire incidents instantly. Once detected, the control panel triggers the suppression agent in less than 10 seconds, minimizing potential damage. Integration with alarms ensures personnel are alerted promptly, enhancing overall safety and response efficiency.


Dynamic Coverage and Customization

Designed for adaptability, this fire suppression solution accommodates coverage areas up to 1000 sq.ft. per unit. Hose lengths, cylinder diameters, and mounting configurations are customizable, addressing unique spatial requirements in commercial and industrial settings. The durable red epoxy powder coating provides both visibility and long-term protection.


Reliable and Eco-Friendly Suppression

Utilizing clean agents like Novec 1230 and FM200, the system offers non-toxic, residue-free extinguishing power. Energy efficiency is prioritized, and the suppression agent is environmentally safe, making it suitable for sensitive areas like server rooms and electrical panels. The refillable design supports longevity and cost-effectiveness.

FAQs of Fire Supression System:


Q: How does the fire suppression system detect and respond to fires?

A: The system uses highly sensitive smoke and heat detectors to identify fire outbreaks promptly. Upon detection, the control panel automatically activates the agent discharge, achieving response times under 10 seconds and releasing the suppressing agent in 1030 seconds to extinguish various fire classes efficiently.

Q: What types of environments and applications can this system be installed in?

A: This fire suppression system is suitable for a wide range of environments, including industrial and commercial buildings, server rooms, and electrical panels. Its customizable components allow flexible installation on walls or ceilings, making it an ideal choice for protecting high-value or sensitive equipment.

Q: When is maintenance required for the fire suppression system?

A: Though maintenance requirements are low, it is recommended to schedule annual inspections to ensure optimal functionality and longevity. The system is designed for durability and reliability, with a typical life expectancy of 10 years.

Q: Where is the best place to mount or install this system?

A: The system should be ceiling or wall-mounted, based on the specific coverage area and potential fire risks within the protected space. Installation guidelines should be followed to optimize effectiveness in targeted locations like server rooms, electrical panels, or open commercial areas.

Q: What is the process for agent refill and maintenance?

A: After an agent discharge or as part of scheduled maintenance, the refillable cylinders can be serviced by trained professionals using approved clean agents such as Novec 1230 or FM200. Routine annual inspections are advised to ensure system integrity and rapid activation ability.

Q: How does alarm integration benefit building safety?

A: Alarm integration, managed via a dedicated control panel, rapidly notifies occupants and triggers emergency protocols when a fire is detected. This enhances situational awareness, supports timely evacuation, and ensures coordinated response efforts during a fire event.

Q: What advantages does the clean agent technology provide?

A: Clean agent technology delivers rapid and effective suppression without leaving residue or causing harm to sensitive equipment. The agents used are non-toxic, environmentally friendly, and meet established safety standards, making them ideal for areas where electronic or irreplaceable assets are present.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Fighting Category

Fire Fighting Panels

Fire Fighting Panels

Minimum Order Quantity : as per customer requirement Unit

Application : Fire detection and suppression control in commercial and industrial premises

Features : Audio/visual alarm, system fault indicator, battery backup, status display

Control Type : Automatic and Manual

Capacity : Supports up to 36 zones

Installation Type : Wallmounted